Part Number Hot Search : 
20KP300A ZS4741A M95160 N5235 477M00 APTGT2 1H104 SMA11
Product Description
Full Text Search
 

To Download TFS70H14 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 TFS70H14.doc
Version 1.1
16.04.2002
VI TELEFILTER
Measurement condition :
Ambient temperature TA: Input power level: Terminating impedances in fc:
Filter specification
TFS 70H14
1/5
25 C 0 dBm for input: for output:
50 50
// 0 pF // 0 pF
Characteristics :
Remark: Reference level for the relative attenuation arel of the TFS 70H14 is the minimum of the pass band attenuation a min. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss ae . The temperature coefficient of frequency Tcf is valid both for the reference frequency f c and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme.
Data
Insertion loss (Reference level) Centre frequency at ambient temperature (fCTA) Pass band : Amplitude ripple in PB : Bandwidth at ambient temperature TA: 1 3 40 dB - band width dB - band width dB - band width arel 4,0 4,25 20 MHz MHz MHz BW ae fc PB
typ. value
tolerance / limit max. 25 dB MHz MHz dB
70,0
MHz
70,0 0,1 fc .. fc 3,85 max. 0,8
8,9 10,9
MHz MHz
min. min. max.
8,0 8,5 11,1
MHz MHz MHz
Relative attenuation fc fc fc 4,0 5,55 ..... fc MHz ..... fc MHz ..... fc
45 1,8 33 0,6 -87 dB s ns ppm/K
max. max. min. max.
1 3 40 2,5
dB dB dB s ns
Group delay ( mean value in PB ): Group delay ripple in PB (p-p): Deviation from linear phase in PB : Temperature coefficient of frequency ( Tcf ) : Frequency deviation of f c over temperature : Operating temperature range Storage temperature range
max. 100 max. 5
fc(Hz) = Tcf(ppm/K) x (T - T o) x fCTA (MHz) - 25 C ... + 80 C - 40 C ... + 85 C
generated:
checked / approved:
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS70H14.doc
Version 1.1
16.04.2002
VI TELEFILTER
Package and pin connection :
Filter specification
(All dimensions in mm)
TFS 70H14
2/5
22,5 Max. 5,0 max. 5,6 max. 2,54 0,2 6x2,54 = 15,62
13 max.
0,45 Dia.
7,62
TFS 70H14 P16
1 2 7
date code: M N P ...
year + week 2000 2001 2002 ...
Pin Pin Pin Pin Pin 14 9 8
14 1 8 7 2, 9
Input Input RF Return Output Output RF Return Pakage Ground
50
matching network :
14
8
IN
TFS 70H14
OUT
1, 2, 7, 9
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS70H14.doc
Version 1.1
16.04.2002
VI TELEFILTER
Filter specification
TFS 70H14
3/5
Stability characteristics :
After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N
2. Vibration:
3. Change of temperature:
4. Resistance to solder heat (reflow): 4;
reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS70H14.doc
Version 1.1
16.04.2002
VI TELEFILTER
Filter specification
TFS 70H14
4/5
Air reflow temperature conditions :
1st and 2nd air reflow profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS70H14.doc
Version 1.1
16.04.2002
VI TELEFILTER
History
Version 1.0 1.1. Reason of changes Generate preliminary specification . typical values added
Filter specification
TFS 70H14
5/5
Name Dunzow W. Pfeiffer
Date 23.11.2001 16.04.2002
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information


▲Up To Search▲   

 
Price & Availability of TFS70H14

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X